Shelter Heat Loss Estimator
Estimate hourly BTU/hr heat loss, heater surplus or deficit, and which surface is leaking the most from your shelter's dimensions, insulation R-values, and temperature difference.
Need to size a backup heat source? Pair with the HVAC BTU sizing calculator or check propane runtime with the generator size calculator.
Estimate your shelter's heat loss
Enter room dimensions, insulation R-values, indoor and outdoor temperatures, and an optional heat source to see BTU/hr loss by surface and heater coverage.
Calculating…
Enter your shelter details above.
How heat loss is calculated
The formula is: Heat Loss (BTU/hr) = (Surface Area / R-value) x Temperature Difference. Each surface, walls, ceiling, floor, and windows, is calculated separately, then summed. A higher R-value means less heat escapes. Doubling R-value from R-11 to R-22 cuts that surface's heat loss in half. This tool adds 25% for air infiltration, which accounts for gaps around doors, outlets, and penetrations.
Tips for success
- Ceiling first, always. Heat rises, so the ceiling is usually the biggest loss surface. In a poorly insulated space, 40% or more of your heat escapes upward. A thermal blanket or extra attic insulation pays back faster than wall improvements.
- Windows lose 5x more heat per square foot than walls. A double-pane window is only R-2 vs R-11 for a standard wall. Hanging heavy blankets over windows during a power outage can cut window losses by more than half.
- Consolidate to one small room. Heating a 150 sq ft bedroom uses far less fuel than a 1,200 sq ft home. An interior room with fewer exterior walls and no windows cuts heat loss dramatically.
- Body heat matters. Two people in a well-insulated small room each add roughly 300 BTU/hr of heat, which can meaningfully offset a small deficit in mild conditions.
- Never use outdoor gas heaters indoors. Grills, torpedo heaters, and unvented combustion appliances produce CO that can incapacitate you within minutes. Only use heaters with an oxygen depletion sensor rated for indoor use.
Practical note
This is an approximation using the standard BTU/hr = (Area / R-value) x delta-T formula plus a 25% infiltration factor. Real heat loss is also affected by thermal bridging, door sealing quality, and foundation type. Add another 10–20% buffer for worst-case planning. This tool is designed for ballpark sizing, not engineering design.
R-value quick reference
- R-1: Single-pane glass, thin plywood, tent fabric. Essentially uninsulated.
- R-3.5: 2x4 stud cavity with no insulation fill, just dead air.
- R-11: 3.5 in fiberglass batt, the standard 2x4 wall fill in pre-1980 homes.
- R-19: 5.5 in fiberglass batt, standard 2x6 wall or floor insulation.
- R-30/R-38: Attic blown-in cellulose or fiberglass, the minimum recommended for cold climates.
- R-2 (window): Double-pane low-E glass. Roughly 6x better than single pane but still the weakest point in most walls.
Common mistakes
- Using zero-head pump ratings for heat. Heater ratings on the box are often at ideal conditions. Propane efficiency drops in cold weather and at low tank pressure. Budget 10–15% less than the rated output.
- Forgetting infiltration. The 25% infiltration factor in this tool is a minimum estimate. Older homes with loose siding, gaps around outlets, and poor door sweeps can add 40–50% over conduction alone.
- Sizing for average cold, not the coldest night. Your shelter will be fine during mild nights. The moment that matters is a 10°F night with a 60°F indoor target and a failing heat source. Size for the worst case.
- Ignoring window count. A room with 4 large windows and R-11 walls can lose more heat through glass than through all four walls combined. Count windows accurately.
- No CO detector when using combustion heat. Even indoor-rated propane heaters should run with a window cracked and a battery-operated CO detector nearby. This is not optional.
FAQ
What's the most effective way to reduce heat loss during a power outage?
Consolidate to a single small room: this is the single biggest impact you can make. Then cover windows with heavy blankets (adds roughly R-2 per layer), seal door gaps, and keep all interior doors closed. A well-insulated 150 sq ft room with two people can stay above 50°F for hours with no added heat source at moderate outdoor temperatures.
How do I find my home's R-values?
Check your home's construction documentation, energy audit report, or ask a contractor to do a thermal inspection. As a rough guide: homes built before 1980 typically have R-11 walls and R-19 ceilings. Homes built after 2000 in cold climates typically have R-15–R-19 walls and R-30–R-38 ceilings. Recent new construction may exceed R-49 in attics.
Can I use a propane heater indoors during a power outage?
Only heaters specifically rated for indoor use, like the Mr. Heater Buddy series, which have oxygen depletion sensors. Never use outdoor propane grills, torpedo heaters, or camp stoves indoors. Even indoor-rated heaters should be used with a window cracked and a battery-operated CO detector running. CO poisoning can incapacitate you silently within minutes.
How long will a 1-lb propane cylinder last on a small heater?
A 1-lb cylinder holds roughly 21,600 BTU of energy. At 9,000 BTU/hr (Mr. Heater Buddy), that's about 2.4 hours. At the low setting (4,000 BTU/hr), closer to 5 hours. A 20-lb tank (420,000 BTU) at the same output gives roughly 46 hours at full output. Stock accordingly for multi-day outages.
Why does this estimate differ from my HVAC sizing calculation?
HVAC sizing adds 20–30% safety margin, accounts for air infiltration, solar gain, and appliance heat, and uses design-day temperatures rather than average outdoor temps. This tool focuses on pure conduction loss through the building envelope as a planning approximation. For actual HVAC sizing, use our HVAC BTU Sizing Calculator or consult a professional.